Suppr超能文献

Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction.

作者信息

Starling M R, Dell'Italia L J, Walsh R A, Little W C, Benedetto A R, Nusynowitz M L

出版信息

J Am Coll Cardiol. 1984 Mar;3(3):789-98. doi: 10.1016/s0735-1097(84)80256-9.

Abstract

To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d degree) and at a distance (d') from the collimator. A simple geometric attenuation correction was performed to obtain absolute left ventricular volume estimates. Using blood sample counts obtained at d degree or d', the attentuation-corrected radionuclide left ventricular end-diastolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-diastolic volumes (r = 0.95 to 0.96). However, both mean radionuclide semiautomated variable left ventricular end-diastolic volumes (179 +/- 100 [+/- 1 standard deviation] and 185 +/- 102 ml, p less than 0.001) were smaller than the average cineangiographic end-diastolic volume (217 +/- 102 ml), and both mean hand-drawn left ventricular end-diastolic volumes (212 +/- 104 and 220 +/- 106 ml) did not differ from the average cineangiographic end-diastolic volume. Using the blood sample counts obtained at d degree or d', the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d degree, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 +/- 98 ml, p less than 0.05) was less than the average cineangiographic end-systolic volume (128 +/- 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume. Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验