Suppr超能文献

Estimates of left-ventricular volumes by equilibrium radionuclide angiography: importance of attenuation correction.

作者信息

Starling M R, Dell'Italia L J, Nusynowitz M L, Walsh R A, Little W C, Benedetto A R

出版信息

J Nucl Med. 1984 Jan;25(1):14-20.

PMID:6233401
Abstract

To compare the accuracy of attenuated and attenuation-corrected equilibrium radionuclide angiographic (RNA) left ventricular (LV) volume estimates, we studied 23 consecutive patients with biplane contrast cineangiography (CINE). Attenuated RNA end-diastolic (ED) and end-systolic (ES) volumes were calculated from background-corrected ED and ES counts obtained from hand-drawn regions of interest that were normalized to cardiac cycles processed, frame rate, and blood activity. A simple, geometric attenuation correction was performed to obtain attenuation-corrected RNA LV volumes. The attenuated and attenuation-corrected RNA LV EDV estimates correlated with the CINE LV EDVs ; however, the attenuation-corrected RNA LV EDV estimates correlated more closely. Also, the average attenuation-corrected RNA LV EDV did not differ significantly from the mean CINE LV EDV. Attenuated and attenuation-corrected RNA LV ESV estimates also correlated with the CINE LV ESVs , but the attenuation-corrected RNA LV ESV estimates correlated more closely. Also, the average attenuation-corrected RNA LV ESV did not differ significantly from the mean biplane CINE LV ESV.