不协调髋关节:一项负荷研究。

The incongruous hip joint: a loading study.

作者信息

Afoke N Y, Byers P D, Hutton W C

出版信息

Ann Rheum Dis. 1984 Apr;43(2):295-301. doi: 10.1136/ard.43.2.295.

Abstract

Hip incongruency was studied by load-displacement and casting methods. Twenty-five joints were loaded in 5 different positions of the walking cycle. Seventeen of them had a space at the apex in all positions, while 3 were congruent at low loads, and the remaining 5 had femoral heads smaller than their acetabula. No trends with age were apparent.

摘要

通过负荷-位移和铸型方法研究髋关节不匹配情况。在步行周期的5个不同位置对25个关节施加负荷。其中17个在所有位置的顶点处都有间隙,3个在低负荷时是匹配的,其余5个的股骨头小于髋臼。未发现与年龄相关的趋势。