用于同时测定未结合胆红素和糖结合胆红素的Ektachem临床化学载玻片。

The Ektachem clinical chemistry slide for simultaneous determination of unconjugated and sugar-conjugated bilirubin.

作者信息

Wu T W, Dappen G M, Spayd R W, Sundberg M W, Powers D M

出版信息

Clin Chem. 1984 Aug;30(8):1304-9.

PMID:6744576
Abstract

Using dual-wavelength spectrometry, we have refined the mordant-based bilirubin slide method (Clin Chem 28:2366-2372, 1982) to co-detect unconjugated bilirubin (Bu) and its sugar conjugates (Bc) in 10 microL of serum. The assay is based on three principles: (a) mono- and diconjugated bilirubins behave spectrally like one fraction (Bc) when bound to the mordant, (b) Bu and Bc are spectrally distinct, and (c) B delta (the bilirubin-albumin complex) is not measured in the film. With known bilirubin mixtures, results by the assay agree with those by nuclear magnetic resonance, by a Jendrassik-Gróf method for total bilirubin, and by a liquid-chromatographic procedure. With patients' sera, the slide correlates with a liquid-chromatography-augmented Jendrassik-Gróf method, according to the following typical regression statistics (in mumol/L): for Bu, slope = 0.992, r = 0.996, intercept = -0.376, Sy X x = 5.08; for Bc, slope = 0.970, r = 0.985, intercept = -0.735, Sy X x = 8.16. The method is precise (for Bu, CV = 5.2% at an average concentration of 16.4 mumol/L, and 4.1% at 66.7 mumol/L; for Bc, CV = 6.5% at 23.4 mumol/L, and 3.8% at 151.7 mumol/L for pools of patients' sera), is relatively interference free, and has potential for extension to further applications.

摘要

我们使用双波长光谱法,改进了基于媒染剂的胆红素玻片法(《临床化学》28:2366 - 2372, 1982),以在10微升血清中同时检测未结合胆红素(Bu)及其糖结合物(Bc)。该检测基于三个原理:(a)单结合和双结合胆红素与媒染剂结合时在光谱上表现为一个组分(Bc);(b)Bu和Bc在光谱上有区别;(c)在薄膜中不检测Bδ(胆红素 - 白蛋白复合物)。对于已知的胆红素混合物,该检测结果与核磁共振、改良Jendrassik - Gróf总胆红素检测法以及液相色谱法的结果一致。对于患者血清,玻片法与液相色谱增强的Jendrassik - Gróf法具有相关性,以下是典型的回归统计数据(单位为μmol/L):对于Bu,斜率 = 0.992,r = 0.996,截距 = -0.376,Sy X x = 5.08;对于Bc,斜率 = 0.970,r = 0.985,截距 = -0.735,Sy X x = 8.16。该方法精密度高(对于Bu测定,患者血清池平均浓度为16.4 μmol/L时CV = 5.2%,66.7 μmol/L时为4.1%;对于Bc测定,23.4 μmol/L时CV = 6.5%,151.7 μmol/L时为3.8%),相对无干扰,并且具有扩展到更多应用的潜力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验