Suppr超能文献

用可编程计算器解读地高辛血药浓度

Interpretation of digoxin blood levels by programmable calculator.

作者信息

Manion C V

出版信息

Am J Hosp Pharm. 1978 Aug;35(8):947-51.

PMID:677144
Abstract

The usefulness of a computer algorithm, for a hand-held calculator, in the calculation of steady-state blood levels of digoxin was studied. The calculator was programmed using the Wagner-Northam steady-state equation. The program was tested on data obtained from the charts of 14 patients recieving digoxin. Blood levels of digoxin were determined by radioimmunoassay. In nine patients, the calculated values correlated well with measured values. In five patients, calculated values did not correlate with measured values; half-life was underestimated in two patients, a charting error was made with one patient and digoxin disappearance was suggested to be unusual in two patients. This study suggests that a measure of scientific precision in planning and monitoring of drug therapy regimens is possible using a programmable calculator.

摘要

研究了一种计算机算法对手持计算器在计算地高辛稳态血药浓度方面的实用性。使用瓦格纳 - 诺瑟姆稳态方程对手持计算器进行编程。该程序在从14名接受地高辛治疗的患者病历中获取的数据上进行了测试。地高辛血药浓度通过放射免疫测定法测定。在9名患者中,计算值与测量值相关性良好。在5名患者中,计算值与测量值不相关;2名患者的半衰期被低估,1名患者存在记录错误,2名患者的地高辛消除情况被认为异常。这项研究表明,使用可编程计算器在药物治疗方案的规划和监测中实现一定程度的科学精确性是可能的。