Suppr超能文献

新生儿血清总钙测量:当前方法的局限性

Total-calcium measurement in serum from neonates: limitations of current methods.

作者信息

Brett E M, Hicks J M

出版信息

Clin Chem. 1981 Oct;27(10):1733-7.

PMID:6793266
Abstract

In the routine analysis for calcium in serum from neonates we noted large discrepancies in icteric samples analyzed by several different methods. The present investigation was undertaken to demonstrate the magnitude of the problem of bilirubin interference in calcium analysis and to assess the specific applicability of commonly used micro-methods in the pediatric or neonatal laboratory. The intention is not to advocate any single methodology but rather to point out inadequacies that must be considered. Colorimetric and fluorometric methods correlated poorly with an atomic absorption spectroscopic method for samples from pediatric patients. In addition, we noted significant interference proportional to the concentration of bilirubin. A fluorescence titration method was shown to be unacceptable for pediatric use because of the variable and unpredictable response to bilirubin interference. The study emphasizes the need for thorough invesigation of methods before they are put to use in the specialized pediatric setting.

摘要

在对新生儿血清钙进行常规分析时,我们注意到采用几种不同方法分析黄疸样本时存在很大差异。本次研究旨在证明胆红素干扰钙分析问题的严重程度,并评估儿科或新生儿实验室常用微量方法的具体适用性。目的不是提倡任何单一方法,而是指出必须考虑的不足之处。对于儿科患者的样本,比色法和荧光法与原子吸收光谱法的相关性较差。此外,我们注意到存在与胆红素浓度成正比的显著干扰。由于对胆红素干扰的反应可变且不可预测,荧光滴定法被证明不适合儿科使用。该研究强调在将方法应用于专门的儿科环境之前,需要对其进行全面研究。