• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous and simultaneous on-line measurements of VO2 and VCO2 during endotracheal anesthesia.

作者信息

Ramanathan S, Chalon J, Satyanarayana T, Arismendy J, Turndorf H

出版信息

Anesth Analg. 1982 Apr;61(4):362-5.

PMID:6802033
Abstract

A single method was developed for the continuous measurement of oxygen consumption (VO2) and carbon dioxide production (VCO2) during endotracheal anesthesia. The total vented flow from a Bain circuit was measured during anesthesia in 28 adult patients and was found to attain at least 97% of a 6-L/min fresh gas inflow (FGI). Therefore, the circuit overflow was assumed to approximate the FGI. Total volume of vented oxygen was calculated by multiplying FGI by oxygen concentration in the vented (mixed expired) gas. VO2 was assessed as the difference between the oxygen volumes entering and leaving the circuit. VCO2 was derived from the product of FGI and mixed expired CO2 concentration. VO2 measured on the Bain circuit correlated with measurements made on a non-breathing circuit (n = 60 pairs, r = 0.99). A good correlation was also found between VCO2 obtained on both circuits (n = 60 pairs, r = 0.99).

摘要

相似文献

1
Continuous and simultaneous on-line measurements of VO2 and VCO2 during endotracheal anesthesia.
Anesth Analg. 1982 Apr;61(4):362-5.
2
The effects of endotracheal suctioning on the accuracy of oxygen consumption and carbon dioxide production measurements and pulmonary mechanics calculated by a compact metabolic monitor.气管内吸痰对紧凑型代谢监测仪所测定的耗氧量、二氧化碳生成量及计算得出的肺力学参数准确性的影响。
Anesth Analg. 2009 Sep;109(3):873-9. doi: 10.1213/ane.0b013e3181b018ee.
3
Noninvasive measurement of pulmonary gas exchange during general anesthesia.全身麻醉期间肺气体交换的无创测量
Anesth Analg. 1980 Apr;59(4):263-9.
4
[The resorption of carbon dioxide from the pneumoperitoneum in laparoscopic cholecystectomy].[腹腔镜胆囊切除术中气腹二氧化碳的吸收]
Anaesthesist. 1993 May;42(5):288-94.
5
[Effects of intraperitoneal CO2 insufflation on hemodynamics and oxygen consumption during intravenous propofol anesthesia combined with epidural block].[静脉注射丙泊酚麻醉联合硬膜外阻滞时腹腔内二氧化碳气腹对血流动力学和氧耗的影响]
Di Yi Jun Yi Da Xue Xue Bao. 2002 Feb;22(2):166-7.
6
Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.使用bymixer测量氧气摄取和二氧化碳排出:在代谢性肺模拟器中的验证
Anesthesiology. 2004 Jun;100(6):1427-37. doi: 10.1097/00000542-200406000-00015.
7
[Effect of low flow anesthesia on respiratory metabolism; continuous measurement of VO2, VCO2 and RQ in surgical patients].[低流量麻醉对呼吸代谢的影响;手术患者VO2、VCO2和RQ的连续测量]
Masui. 1987 Mar;36(3):329-39.
8
[Measurement by mass spectrometry of oxygen consumption and carbon dioxide production in mechanically ventilated patients].[机械通气患者耗氧量和二氧化碳产生量的质谱测量]
Pathol Biol (Paris). 1984 Mar;32(3):209-14.
9
A Device for the Quantification of Oxygen Consumption and Caloric Expenditure in the Neonatal Range.一种用于新生儿范围内氧耗量和热量消耗定量的设备。
Anesth Analg. 2018 Jul;127(1):95-104. doi: 10.1213/ANE.0000000000003308.
10
[The effects of position and ventilation during thoracotomy on oxygen uptake and carbon dioxide elimination in humans].[开胸手术期间体位和通气对人体氧摄取和二氧化碳排出的影响]
Masui. 1992 Apr;41(4):625-30.

引用本文的文献

1
Calculation of O2 consumption during low-flow anesthesia from tidal gas concentrations, flowmeter, and minute ventilation.根据潮气量浓度、流量计和分钟通气量计算低流量麻醉期间的氧气消耗量。
J Clin Monit Comput. 2004 Dec;18(5-6):325-32. doi: 10.1007/s10877-005-4299-1.