Rane R L, Yut J P, Berger K W
J Am Audiol Soc. 1978 May-Jun;3(6):241-4.
The preoperative audiometric and electroacoustic impedance test results of 24 surgically confirmed otosclerotics are reviewed with special attention given to the direction of needle deflection during acoustic reflex testing. Information on the direction of needle deflection during acoustic reflex testing was gathered at 5 or 10 dB above reflex threshold. In 12 of the 24 patients acoustic reflexes were present, and in each case the response included negative needle deflections. The presence or absence of the acoustic reflex seemed to be related to the reported duration of the hearing loss.
回顾了24例经手术确诊的耳硬化症患者的术前听力测定和电声阻抗测试结果,特别关注了声反射测试期间针偏转的方向。在高于反射阈值5或10分贝时收集了声反射测试期间针偏转方向的信息。24例患者中有12例存在声反射,且每种情况下反应均包括负向针偏转。声反射的存在与否似乎与所报告的听力损失持续时间有关。