• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Colocolostomy and coloproctostomy utilizing the circular intraluminal stapling devices.

作者信息

Kennedy H L, Rothenberger D A, Goldberg S M, Nivatvongs S, Balcos E G, Christenson C E, Nemer F D, Schottler J L

出版信息

Dis Colon Rectum. 1983 Mar;26(3):145-8. doi: 10.1007/BF02560155.

DOI:10.1007/BF02560155
PMID:6825518
Abstract

Coloproctostomy or colocolostomy by peranal insertion of a circular stapling device was performed on 265 patients between January 1978, and June 1981. A low anterior resection was performed in 174 patients. Stapler-related technical complications occurred in 52 patients (20 per cent). Complementary transverse colostomies were performed in 11 patients, of which seven were performed on the first 30 patients. Intraoperative complications occurred in 18 patients (7 per cent). Twenty-six major postoperative complications occurred (10 per cent), and clinical anastomotic leaks occurred in eight patients (3 per cent). Four postoperative deaths occurred (1.5 per cent). This study concludes that (1) coloproctostomy or colocolostomy can be safely performed by transanal insertion of a circular stapling device, (2) these instruments allow a sphincter-preserving procedure to be performed for lesions in the low and midrectum (5 to 10 cm from the anal verge) with an acceptable early morbidity and mortality, and (3) the majority of stapler-related technical complications can be managed without protecting colostomy.

摘要

相似文献

1
Colocolostomy and coloproctostomy utilizing the circular intraluminal stapling devices.
Dis Colon Rectum. 1983 Mar;26(3):145-8. doi: 10.1007/BF02560155.
2
Anal pressures impaired by stapler insertion during colorectal anastomosis: a randomized, controlled trial.结直肠吻合术中吻合器插入对肛门压力的影响:一项随机对照试验
Dis Colon Rectum. 1999 Jan;42(1):89-95. doi: 10.1007/BF02235189.
3
Use of the circular stapler in 1000 consecutive colorectal anastomoses: experience of one surgical team.连续1000例结直肠吻合术中圆形吻合器的应用:一个手术团队的经验
Surgery. 1995 Feb;117(2):140-5. doi: 10.1016/s0039-6060(05)80077-7.
4
A comparison of circular stapling devices in colorectal anastomoses.结直肠吻合术中圆形吻合器的比较。
Br J Surg. 1982 Jan;69(1):19-22. doi: 10.1002/bjs.1800690107.
5
Use of the stapler in anterior resection for cancer of the rectosigmoid.
Isr J Med Sci. 1983 Feb;19(2):128-33.
6
Double stapling technique for low anterior resection.
Dis Colon Rectum. 1983 Apr;26(4):231-5. doi: 10.1007/BF02562484.
7
Anterior resection using the circular stapling instrument: a Singapore experience.使用圆形吻合器进行前切除术:新加坡的经验。
Aust N Z J Surg. 1986 Dec;56(12):919-22. doi: 10.1111/j.1445-2197.1986.tb01855.x.
8
[Mechanical suture during resection of the rectum through the abdomen (author's transl)].经腹直肠切除术中的机械缝合(作者译)
Acta Chir Belg. 1979 Jul-Aug;78(4):259-64.
9
Double stapling technique in the management of rectal tumours.
Acta Chir Scand. 1986 Dec;152:743-7.
10
Peranal coloanal anastomosis following low anterior resection for rectal carcinoma.直肠癌低位前切除术后经肛门结肠肛管吻合术
Dis Colon Rectum. 1985 Aug;28(8):576-81. doi: 10.1007/BF02554147.

引用本文的文献

1
The double stapling technique for low anterior resection. Results, modifications, and observations.
Ann Surg. 1990 Jun;211(6):745-51; discussion 751-2. doi: 10.1097/00000658-199006000-00014.