Abstract

We have simultaneously measured T4 and TSH concentrations from 93,000 consecutive filter paper blood samples received by the Quebec network for Genetic Medicine. T4 was measured using the Micromedic Automated System and TSH was measured by RIA kits from Pharmacia and Becton Dickinson, each for a 6-month period. Statistical analyses to assess quality control parameters for the various methods revealed that the T4 assay had greater precision and reproducibility than either of the 2 commercially available TSH kits. The number of false negative results was similar for both methods. Eight infants with ectopic thyroid glands were correctly detected by the T4 method. One infant with secondary hypothyroidism was detected by the T4 approach and missed by the TSH methodology. Three infants overall would have been missed using either the T4 or TSH approach. These data indicate that primary T4 screening has similar sensitivity compared to TSH kits for mass screening programs for congenital hypothyroidism.

摘要

我们从魁北克遗传医学网络接收的93000份连续滤纸血样中同时测量了T4和TSH浓度。T4使用Micromedic自动化系统进行测量,TSH使用Pharmacia和Becton Dickinson的放射免疫分析试剂盒进行测量,每种方法均为期6个月。评估各种方法质量控制参数的统计分析表明,T4检测比两种市售TSH试剂盒中的任何一种都具有更高的精密度和可重复性。两种方法的假阴性结果数量相似。T4方法正确检测出8例异位甲状腺婴儿。T4方法检测出1例继发性甲状腺功能减退婴儿,而TSH方法未检测到。总体而言,使用T4或TSH方法会漏诊3例婴儿。这些数据表明,在先天性甲状腺功能减退症的大规模筛查项目中,原发性T4筛查与TSH试剂盒具有相似的敏感性。