Suppr超能文献

Contrast enhancement technique for dynamic hepatic computed tomographic scanning.

作者信息

Foley W D, Berland L L, Lawson T L, Smith D F, Thorsen M K

出版信息

Radiology. 1983 Jun;147(3):797-803. doi: 10.1148/radiology.147.3.6844616.

Abstract

A study comparing precontrast and survey postcontrast dynamic computed tomographic (CT) scanning was performed on 60 patients who had suspected hepatic metastases. An incremental dynamic technique was used during and following a 50-g iodine load administered over two minutes. The survey postcontrast dynamic technique was superior in both sensitivity and contrast differentiation and yielded no known false-negative examinations. No postprocedure renal dysfunction was observed. High-dose contrast-material delivery in conjunction with incremental dynamic CT scanning appears to be the most suitable technique for performing postcontrast hepatic CT examinations.