Abstract

To reduce the radiation exposure received by young scoliosis patients during treatment, six changes in technique were instituted: (1) a posteroanterior projection, (2) specially designed leaded acrylic filters, (3) a high-speed screen-film system, (4) a specially designed cassette-holder and grid, (5) a breast-shield, and (6) additional filtration in the x-ray tube the thyroid, breast, and abdominal areas were made on an Alderson phantom. They revealed an eightfold reduction in abdominal exposure for both the posteroanterior and the lateral radiographys. There was a twentyfold reduction in exposure to the thyroid for the posteroanterior radiography from 100 to less than five milliroentgens and for the lateral radiograph there was a 100-fold reduction from 618 to six milliroentgens. For the breasts there was a sixty-ninefold reduction from 344 to less than five milliroentgens for the posteroanterior radiography and a fifty-fivefold reduction from 277 to less than five milliroentgens for the lateral radiograph. These reductions in exposure were obtained without significant loss in the quality of the radiographs and in most instances with an improvement in the over-all quality of the radiograph due to the more uniform exposure.

摘要

为减少年轻脊柱侧弯患者在治疗期间所接受的辐射暴露,采取了六项技术改进措施:(1)后前位投照;(2)特制的铅丙烯酸滤线器;(3)高速增感屏-胶片系统;(4)特制的暗盒架和滤线栅;(5)乳房防护板;(6)在X射线管中增加滤过。在Alderson人体模型上对甲状腺、乳房和腹部区域进行了检测。结果显示,后前位和侧位X线摄影时腹部暴露剂量均降低了8倍。后前位X线摄影时甲状腺暴露剂量从100毫伦琴降至不足5毫伦琴,降低了20倍;侧位X线摄影时从618毫伦琴降至6毫伦琴,降低了100倍。乳房部位,后前位X线摄影时从344毫伦琴降至不足5毫伦琴,降低了69倍;侧位X线摄影时从277毫伦琴降至不足5毫伦琴,降低了55倍。这些暴露剂量的降低并未导致X线片质量显著下降,而且在大多数情况下,由于曝光更加均匀,X线片的整体质量有所提高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验