Brunelle F, Kunstlinger F, Quillard J
Radiology. 1983 Aug;148(2):413-5. doi: 10.1148/radiology.148.2.6867333.
Endovascular electrocoagulation of the anterior tibial artery in dogs was performed with two different bipolar electrodes. Follow-up showed revascularization when a short-tip electrode was used, but no revascularization when a long-tip electrode was used. Histologic study showed complete occlusion of the artery by an organized thrombus adherent to the vessel wall.
使用两种不同的双极电极对犬的胫前动脉进行血管内电凝。随访显示,使用短尖端电极时血管再通,但使用长尖端电极时未出现血管再通。组织学研究显示,动脉被附着于血管壁的机化血栓完全阻塞。