Two totally deaf patients who had received multiple-channel cochlear implants were tested using a speech "tracking" procedure in which they had to repeat verbatim passages of connected discourse. Their performance was assessed by calculating the tracking rate (words per minute) each session. Testing was carried out under two conditions--lipreading alone and lipreading in conjunction with a multiple-channel cochlear implant and laboratory speech processor. Lipreading with the cochlear implant increased the tracking rates by a factor of four for one patient and by a factor of two for the other when compared with lipreading alone.

摘要

两名接受了多通道人工耳蜗植入的全聋患者,采用言语“追踪”程序进行测试,在该程序中他们必须逐字重复连贯话语的段落。每次测试通过计算追踪率(每分钟字数)来评估他们的表现。测试在两种条件下进行——单独唇读以及唇读与多通道人工耳蜗及实验室言语处理器相结合。与单独唇读相比,一名患者在唇读时结合人工耳蜗,追踪率提高了四倍,另一名患者提高了两倍。