用于热水加湿器的温度报警和切断系统。

Temperature alarm and cut-out system for use with heated water humidifiers.

作者信息

Whitehurst P, St Andrew D

出版信息

Br J Anaesth. 1980 May;52(5):557-8. doi: 10.1093/bja/52.5.557.

Abstract

The temperature of the inspired humidified gases of an intubated patient may be monitored accurately, close to the airway, by a commercially available thermistor probe and alarm/cut-out device for use with heated water humidifiers. The apparatus is designed to alarm when the inspired gas temperature exceeds the pre-set temperature and when the thermistor probe is in open or short circuit. When the temperature alarm is activated, the humidifier heater is switched off automatically, thus preventing prolonged transmission of excessively hot gases to the airway. The apparatus has been used successfully in this hospital for several months, requiring minimal observer attention and maintenance.

摘要

对于插管患者,可使用市售的热敏电阻探头以及与热水加湿器配套的警报/切断装置,在靠近气道的位置准确监测其吸入的湿化气体的温度。该设备设计用于在吸入气体温度超过预设温度以及热敏电阻探头出现开路或短路时发出警报。当温度警报启动时,加湿器加热器会自动关闭,从而防止过热气体长时间传输至气道。该设备已在本院成功使用数月,只需极少的观察和维护。