Simionescu L, Stoenescu D, Handoca A, Dimitriu V, Oprescu M, Taşcă C, Damian A, Cernăianu N, Kornfeld I
Endocrinologie. 1978 Jul-Sep;16(3):219-22.
A radioimmunoassay (RIA) double antibody system for human thyroglobulin (Tgl) was developed with a sensitivity of 2.5 ng/ml T3 and T4 did not interfere in the antibody Tgl binding. The blood was collected pre-, intra- and 24 hrs post-thyroidectomy from 50 females and 4 males diagnosed as polynodular goiter, hyperthyroidism, chronic thyroiditis and thyroid cancer. The ratios of the intra- and post-operatory values versus pre-operatory values were calculated. The basal values in the patients having thyroid troubles varied within very large limits (two orders of magnitude) and these values could not be clearly correlated to the thyroid pathology, However, in untreated hyperthyroid patients the basal values exceeded 100 ng/ml, while in medullary carcinoma they were near the sensitivity limit of the technique. The intra-operatory values varied within the percentual area (thyroid carcinoma), multiplicative area (polynodular goiter and some cases of hyperthyroidism) and the order of magnitude area (hyperthyroid patients and some of the polynodular goiters). The value of the RIA measurement of the Tgl in the serum as an adjuvant in the post-treatment follow up of thyroid patients is discussed.
建立了一种用于人甲状腺球蛋白(Tgl)的放射免疫分析(RIA)双抗体系统,其灵敏度为2.5 ng/ml,T3和T4不干扰抗体与Tgl的结合。从50名女性和4名男性中收集甲状腺切除术前、术中和术后24小时的血液,这些患者被诊断为多结节性甲状腺肿、甲状腺功能亢进、慢性甲状腺炎和甲状腺癌。计算术中及术后值与术前值的比值。患有甲状腺疾病的患者的基础值在非常大的范围内变化(两个数量级),并且这些值与甲状腺病理情况没有明显的相关性。然而,在未经治疗的甲状腺功能亢进患者中,基础值超过100 ng/ml,而在髓样癌中,它们接近该技术的灵敏度极限。术中值在百分比区域(甲状腺癌)、倍数区域(多结节性甲状腺肿和一些甲状腺功能亢进病例)和数量级区域(甲状腺功能亢进患者和一些多结节性甲状腺肿)内变化。讨论了血清中Tgl的RIA测量值作为甲状腺患者治疗后随访辅助手段的价值。