Saab G A, Green R, Crosby W H
Am J Clin Pathol. 1978 Aug;70(2):275-9. doi: 10.1093/ajcp/70.2.275.
The authors present a rapid modification of the tube immunoradiometric assay for serum ferritin quantitation. The method involves gentle rotatory mixing of the tube contents at ambient temperature and can be performed in a few hours. Variables affecting different stages of the assay were systematically investigated. The performance characteristics of the shortened assay in terms of reproducibility, sensitivity and recovery were then validated. Results with this method correlate well with those obtained by the conventional assay.
作者介绍了一种用于血清铁蛋白定量的管免疫放射分析方法的快速改进方法。该方法包括在室温下轻柔旋转混合管内物质,可在数小时内完成。系统研究了影响该分析不同阶段的变量。然后对缩短后的分析方法在重复性、灵敏度和回收率方面的性能特征进行了验证。该方法的结果与传统分析方法所得结果相关性良好。