Stimulating electrodes were placed in the posterior portion of the epidural space in the upper thoracic spinal region in 28 patients with upper motor neuron disorders. Parameters of stimulation commonly used for chronic stimulation were a 200 microsecond pulse width, 22 Hz repetition rate, and 5 ma amplitude. Using a 16 gauge Touhy needle, platinum electrodes were passed between the posterior vertebral processes into and up the spinal epidural space to upper thoracic locations. Passive implanted receivers, powered and controlled by external RF transmitter/pulse-generator devices, were employed to provide the stimulus current to the electrodes. A description of available systems, problems and diagnosis of problems, and future directions is presented. This is based on studies in patients with stimulation systems implanted for more than six months.

摘要

在28例上运动神经元疾病患者的上胸段脊髓区域硬膜外间隙后部放置刺激电极。慢性刺激常用的刺激参数为200微秒的脉冲宽度、22赫兹的重复频率和5毫安的幅度。使用16号Touhy针,将铂电极经椎骨后突之间插入脊髓硬膜外间隙并向上至胸段上部位置。采用由外部射频发射器/脉冲发生器装置供电和控制的无源植入式接收器向电极提供刺激电流。本文介绍了现有系统、问题及问题诊断,以及未来发展方向。这是基于对植入刺激系统超过6个月的患者的研究。