Suppr超能文献

脊髓交流电刺激对大鼠急性脊髓损伤恢复的影响。

Effect of alternating current stimulation of the spinal cord on recovery from acute spinal cord injury in rats.

作者信息

Wallace M C, Tator C H, Gentles W M

出版信息

Surg Neurol. 1987 Oct;28(4):269-76. doi: 10.1016/0090-3019(87)90305-3.

Abstract

The therapeutic value of electrical stimulation of the spinal cord was studied in rats injured by acute compression of the spinal cord. Twenty adult Wistar rats underwent cord compression at T6-7 by the extradural clip compression technique at a force of 125 g for 1 minute. After injury and group randomization, stimulating electrodes were placed extradurally, proximal and distal to the injury site, and attached to a small, implantable receiver-stimulator. The receiver was secured to the paraspinal muscles and implanted subcutaneously, overlying the thoracic spine. The animals were maintained in specially designed cages with encircling antennae attached to radio frequency transmitters. The 10 treatment animals were subjected to a 460-kHz electromagnetic field, pulsed at a frequency of 10 Hz. The receivers converted the pulsed radio frequency into square-wave pulses at the cord electrodes (width 1 ms, frequency 10 Hz). The 10 control animals were exposed to a similar field but with a frequency below the range of the tuned receiver, and therefore they did not receive the square-wave pulse. Clinical recovery was assessed by the inclined plane technique which measures the maximum angle of inclination attained without falling. After 15 weeks of continuous spinal cord stimulation, the inclined plane performance was not significantly different between the two groups (treatment group mean, 44.4 +/- 5.4; control group mean, 41.7 +/- 7.9). This is the first experimental study of the effect of long-term continuous electrical stimulation on spinal cord recovery in mammals. The methods required and the technical aspects involved in achieving continuous stimulation, and the guidelines for future study of this modality are discussed.

摘要

研究了脊髓电刺激对急性脊髓压迫损伤大鼠的治疗价值。20只成年Wistar大鼠采用硬膜外夹压技术,在T6 - 7节段以125克的力压迫脊髓1分钟。损伤后进行分组随机化,将刺激电极置于损伤部位近端和远端的硬膜外,并连接到一个小型可植入式接收器 - 刺激器上。接收器固定在椎旁肌肉上并皮下植入,覆盖胸椎。将动物饲养在特别设计的笼子里,笼子周围附有与射频发射器相连的天线。10只治疗组动物接受频率为10赫兹、脉冲频率为460千赫兹的电磁场。接收器将脉冲射频转换为脊髓电极处的方波脉冲(宽度1毫秒,频率10赫兹)。10只对照组动物暴露于类似的场,但频率低于调谐接收器的范围,因此它们没有接收到方波脉冲。通过斜面技术评估临床恢复情况,该技术测量在不摔倒的情况下达到的最大倾斜角度。连续脊髓刺激15周后,两组的斜面表现无显著差异(治疗组平均值为44.4±5.4;对照组平均值为41.7±7.9)。这是关于长期连续电刺激对哺乳动物脊髓恢复影响的首次实验研究。讨论了实现连续刺激所需的方法和涉及的技术方面,以及该模式未来研究的指导原则。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验