Pledger D R, Belfield A, Strömberg P
J Clin Chem Clin Biochem. 1981 Sep;19(9):943-6. doi: 10.1515/cclm.1981.19.9.943.
A comparison of serum pregnancy specific beta 1 glycoprotein analysis by enzyme linked immunosorbent assay and radioimmunoassay has been made. Excellent correlation was obtained between the two methods but radioimmunoassay was found to be more precise and to have a lower detection limit than enzyme linked immunosorbent assay. Using the more sensitive radioimmunoassay system, 2 out of 10 control male sera were found to contain detectable levels of pregnancy specific beta 1 glycoprotein. Sequential results are presented on patients with diagnosed malignant teratoma of testis who were undergoing chemotherapy.
对采用酶联免疫吸附测定法和放射免疫测定法进行血清妊娠特异性β1糖蛋白分析进行了比较。两种方法之间具有良好的相关性,但发现放射免疫测定法比酶联免疫吸附测定法更精确且检测限更低。使用更灵敏的放射免疫测定系统,在10份男性对照血清中有2份被发现含有可检测水平的妊娠特异性β1糖蛋白。文中给出了正在接受化疗的确诊睾丸恶性畸胎瘤患者的系列检测结果。