Suppr超能文献

维生素D代谢物测量的实验室间差异1)

Interlaboratory variation of vitamin D1) metabolite measurements.

作者信息

Jongen M J, van der Vijgh W J, van Beresteyn E C, van den Berg H, Bosch R, Hoogenboezem T, Visser T J, Netelenbos J C

出版信息

J Clin Chem Clin Biochem. 1982 Oct;20(10):753-6. doi: 10.1515/cclm.1982.20.10.753.

Abstract

Interlaboratory variation of the measurement of 25-hydroxy vitamin D, 24,25-dihydroxy vitamin D and 1,25-dihydroxy vitamin D by six laboratories in the Netherlands was studied. Three different serum samples and two different standard solutions of each metabolite were assayed. Substantial interlaboratory variation was found for the measurement of serum samples. The mean interlaboratory CV's for the 25-hydroxy vitamin D, 24,25-dihydroxy vitamin D and 1,25-dihydroxy vitamin D assays in the three sera were 48%, 38% and 20% respectively. The measurement of standard solutions of all metabolites showed relative little variation (mean CV 8%). The small number of samples allowed no evaluation of intralaboratory variation. The much higher CV's of the measurement of serum samples, when compared to standard solutions, may be attributed to differences in extraction and purification procedures which are probably responsible for the presence of varying amounts of interfering substances during the final quantification of metabolites.

摘要

研究了荷兰六个实验室对25-羟基维生素D、24,25-二羟基维生素D和1,25-二羟基维生素D测量的实验室间差异。对三种不同的血清样本以及每种代谢物的两种不同标准溶液进行了检测。发现血清样本测量存在显著的实验室间差异。三种血清中25-羟基维生素D、24,25-二羟基维生素D和1,25-二羟基维生素D检测的实验室间平均变异系数分别为48%、38%和20%。所有代谢物标准溶液的测量显示变异相对较小(平均变异系数8%)。样本数量较少,无法评估实验室内差异。与标准溶液相比,血清样本测量的变异系数要高得多,这可能归因于提取和纯化程序的差异,这些差异可能是在代谢物最终定量过程中存在不同量干扰物质的原因。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验