Ashby C D, Lewis J E, Nelson J C
Clin Chem. 1978 Oct;24(10):1734-7.
A versatile radioimmunoassay procedure has been developed to specifically assay gentamicin, tobramycin, or amikacin. Iodinated derivatives of these three antibiotics were prepared by a modified Bolton and Hunter procedure. A single reagent system composed of a pool of three very specific antisera was used in the procedure. The antisera combination did not alter the specificity of the procedure. Validation of the assay of the three antibiotics included studies of parallelism, accuracy, precision, reproducibility, and method comparison with other radioimmunoassay procedures involving single antiserum systems. We discuss the application of this multiple assay capability to other procedures involving use of immunochemicals.
已开发出一种通用的放射免疫分析方法,用于特异性检测庆大霉素、妥布霉素或阿米卡星。这三种抗生素的碘化衍生物是通过改良的博尔顿-亨特法制备的。该方法使用了由三种高度特异性抗血清组成的单一试剂系统。抗血清组合并未改变该方法的特异性。对这三种抗生素检测方法的验证包括平行性、准确性、精密度、重现性研究,以及与其他涉及单一抗血清系统的放射免疫分析方法的方法比较。我们讨论了这种多重检测能力在其他涉及免疫化学物质使用的方法中的应用。