We have evaluated a new diagnostic kit for the determination of total estrogens in serum or plasma of pregnant women by means of an enzyme-immuno-assay. Within-run precision had a coefficient of variation of 4.7-4.9% for total estrogen concentrations of 400 to 2000 nmol/l. For the same range of concentrations, day-to-day precision was found to be 5.9-8.9%. Mean analytic recovery of unconjugated estriol was 102%. Enzymatic hydrolysis of different estrogen conjugates was shown to be virtually complete. The antiserum used in the assay has the same affinity for estrone, estradiol and estriol. Preliminary clinical studies included 14 pregnant women. The results suggest that the determination of total estrogens in pregnancy plasma can be used to monitor fetoplacental function in much the same way as urine total estrogens are used.

摘要

我们通过酶免疫测定法评估了一种用于测定孕妇血清或血浆中总雌激素的新型诊断试剂盒。对于400至2000 nmol/l的总雌激素浓度,批内精密度的变异系数为4.7 - 4.9%。对于相同浓度范围,日间精密度为5.9 - 8.9%。未结合雌三醇的平均分析回收率为102%。不同雌激素结合物的酶促水解显示几乎完全。该测定中使用的抗血清对雌酮、雌二醇和雌三醇具有相同的亲和力。初步临床研究包括14名孕妇。结果表明,妊娠血浆中总雌激素的测定可用于监测胎儿胎盘功能,其方式与尿总雌激素的使用方式大致相同。