Schor C, Gibson J, Hsu M, Mah M
Am J Optom Physiol Opt. 1981 Nov;58(11):930-8. doi: 10.1097/00006324-198111000-00004.
The use of rotating gratings for the treatment of amblyopia was subjected to a controlled clinical trial. A treatment group (N = 19) observed rotating gratings for 15 min per week for 10 weeks and a control group (N = 19) observed a blank rotating disk for the same period. Both groups of amblyopes performed visually guided tasks to maintain their interest during treatment. Data were acquired in a double-masked manner. A second control group (N = 4) underwent weekly acuity evaluation without any form of treatment. Visual acuity was evaluated before and after each session and analyzed with a linear regression fit to a probit transform by a minicomputer. By using a criterion change in acuity of 10% Snell Sterling, we found no significant change of acuity in any group or between groups. These results demonstrate that rotating gratings are an insignificant variable in the treatment of amblyopia.
对使用旋转光栅治疗弱视进行了一项对照临床试验。一个治疗组(N = 19)每周观察旋转光栅15分钟,共观察10周;一个对照组(N = 19)在同一时期观察一个空白旋转圆盘。两组弱视患者在治疗期间都执行视觉引导任务以保持他们的兴趣。数据以双盲方式获取。第二个对照组(N = 4)每周进行视力评估但不接受任何形式的治疗。在每次疗程前后评估视力,并通过小型计算机对概率变换进行线性回归拟合分析。通过使用视力变化10%斯内伦标准,我们发现任何组内或组间的视力均无显著变化。这些结果表明,旋转光栅在弱视治疗中是一个无显著意义的变量。