• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

小儿血液分析仪D系统(作者译)

[The system Hemalog D in paediatrics (author's transl)].

作者信息

Maier M, Josso F

出版信息

Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):269-72.

PMID:704341
Abstract

The Hemalog D was studied at the Childrens' Hospital to examine its performance in paediatrics. All the subjects studied were children with non-hematologic diseases; both venous and capillary blood samples were taken. The differential was performed in parallel by the Hemalog D and the technicians of the Hematology Laboratory. There was an excellent correlation between the two methods for neutrophils and lymphocytes, a good correlation for eosinophils and a weaker correlation for monocytes and basophils. No difficulties were encountered during the course of the study. It must be noted, however that capillary samples caused a Low Rate alarm to be registered.

摘要

在儿童医院对Hemalog D进行了研究,以检验其在儿科的性能。所有研究对象均为患有非血液系统疾病的儿童;采集了静脉血和毛细血管血样本。由Hemalog D和血液学实验室的技术人员同时进行分类计数。两种方法在中性粒细胞和淋巴细胞方面具有极佳的相关性,在嗜酸性粒细胞方面具有良好的相关性,在单核细胞和嗜碱性粒细胞方面相关性较弱。在研究过程中未遇到任何困难。然而,必须指出的是,毛细血管样本导致了低速率警报的记录。

相似文献

1
[The system Hemalog D in paediatrics (author's transl)].小儿血液分析仪D系统(作者译)
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):269-72.
2
[Use of the LARC system in a laboratory specializing in hematology (author's transl)].
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):273-87.
3
[Practical aspects of the routine hospital use of the Hemalog D (author's transl)].医院常规使用Hemalog D的实际情况(作者译)
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):257-67.
4
[Testing the hemalog D in a hematology department of a general hospital in Paris (author's transl)].
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):223-48.
5
[Statistical study of results of Hemalog D (author's transl)].血细胞分析仪D检测结果的统计学研究(作者译)
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):249-56.
6
[A new parameter for chronic lymphocytic leukemia : determination of the large lymphocytes by means of Hemalog D (author's transl)].
Nouv Rev Fr Hematol (1978). 1978 Jun 10;20(2):311-5.
7
Evaluation of the Abbott CELL-DYN 4000 hematology analyzer.雅培CELL-DYN 4000血液分析仪评估
Am J Clin Pathol. 2000 Apr;113(4):497-505. doi: 10.1309/L7LC-6KKJ-12G2-196W.
8
[Evaluation of Abbott CD 3500 in severe leukopenia].[雅培CD 3500在严重白细胞减少症中的评估]
Nouv Rev Fr Hematol (1978). 1994 Jul;36 Suppl 2:S117-21.
9
[Hemalog--a fully automated system for haematologie (author's transl)].[血液分析仪——一种血液学全自动系统(作者译)]
Biomed Tech (Berl). 1975 Feb;20(1):33-8.
10
Analytic performance of the PENTRA 80 automated blood cell analyzer for the evaluation of normal and pathologic WBCs.用于评估正常和病理性白细胞的PENTRA 80全自动血细胞分析仪的分析性能。
Am J Clin Pathol. 2005 Feb;123(2):206-14.