Suppr超能文献

助听器验配中听阈水平与最舒适响度水平的比较。

Comparison of hearing threshold level and most comfortable loudness level in hearing aid prescription.

作者信息

Berger K W, Hagberg E N, Varavvas D M, Vottero D M

出版信息

Ear Hear. 1982 Jan-Feb;3(1):30-3. doi: 10.1097/00003446-198201000-00006.

Abstract

In three experiments, the predictability of the hearing aid gain actually used by clients was compared with that predicted by using data based upon hearing threshold level and data based upon most comfortable loudness level. At the frequencies tested, the mean difference between the predicted and obtained gain was smaller when based upon prediction from the hearing threshold level. It is concluded that from the standpoint of predicting user's gain, the hearing threshold level provides greater accuracy than does most comfortable loudness level.

摘要

在三项实验中,将客户实际使用的助听器增益的可预测性与基于听力阈值水平的数据和基于最舒适响度水平的数据所预测的可预测性进行了比较。在所测试的频率上,基于听力阈值水平进行预测时,预测增益与实际获得的增益之间的平均差异较小。得出的结论是,从预测用户增益的角度来看,听力阈值水平比最舒适响度水平提供更高的准确性。