Suppr超能文献

采用高效液相色谱法结合紫外和安培检测法分析尿液中对乙酰氨基酚代谢物。

Analysis of acetaminophen metabolites in urine by high-performance liquid chromatography with UV and amperometric detection.

作者信息

Wilson J M, Slattery J T, Forte A J, Nelson S D

出版信息

J Chromatogr. 1982 Feb 12;227(2):453-62. doi: 10.1016/s0378-4347(00)80398-9.

Abstract

Acetaminophen and several of its metabolites are separated isocratically on a reversed-phase (C18) column using a mobile phase of 7% methanol and 0.75% glacial acetic acid in 0.1 M KH2PO4. Metabolites that can be separated include the sulfate, glucuronide, cysteine, and mercapturic acid conjugates of acetaminophen, as well as 3-hydroxyacetaminophen, 3-methoxyacetaminophen, and 3-methylthioacetaminophen. Although all of the metabolites can be detected by UV spectrophotometry, the sensitivity limits of detection are improved significantly for acetaminophen and all of the metabolites except the sulfate and glucuronide, by amperometric detection (electrochemical) of the same sample as it elutes from the UV detector. Minimal detectable limits (signal-to-noise ratio greater than or equal to 2) for acetaminophen and its metabolites, other than the glucuronide and sulfate conjugates, were in the order of 1--2 ng injected on column using UV detection at 248 nm, and 0.1--0.5 ng using electrochemical detection at + 0.60 V with reference to an Ag/AgCl standard electrode.

摘要

对乙酰氨基酚及其几种代谢物在反相(C18)柱上进行等度分离,流动相为0.1M磷酸二氢钾中含7%甲醇和0.75%冰醋酸。可分离的代谢物包括对乙酰氨基酚的硫酸盐、葡萄糖醛酸苷、半胱氨酸和巯基尿酸共轭物,以及3 - 羟基对乙酰氨基酚、3 - 甲氧基对乙酰氨基酚和3 - 甲硫基对乙酰氨基酚。虽然所有代谢物都可用紫外分光光度法检测,但通过对从紫外检测器洗脱的同一样品进行安培检测(电化学检测),对乙酰氨基酚以及除硫酸盐和葡萄糖醛酸苷之外的所有代谢物的检测灵敏度极限都有显著提高。对乙酰氨基酚及其代谢物(除葡萄糖醛酸苷和硫酸盐共轭物外)的最低检测限(信噪比大于或等于2),在248nm处用紫外检测时,进样量在柱上为1 - 2ng左右,而在相对于Ag/AgCl标准电极+0.60V下用电化学检测时为0.1 - 0.5ng。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验