Ménardo J L, Bousquet J, Michel F B
Ann Allergy. 1982 Apr;48(4):235-9.
Three prick test methods were compared in the diagnosis of mite allergy--the Morrow Brown standardized needle, the Multi-test device and a modified prick test. They were compared with the intradermal test and with specific IgE antibodies measured by RAST. Thirty patients and 10 control subjects were tested. The intradermal test was always positive in patients but induced two false positive reactions. All prick test methods gave false negative reactions. The Multi-Test device produced intermediate reactions between prick test and intradermal test.
为诊断螨过敏,对三种点刺试验方法进行了比较,即莫罗·布朗标准化针头、多测试装置和改良点刺试验。将它们与皮内试验以及通过放射变应原吸附试验(RAST)测定的特异性IgE抗体进行比较。对30名患者和10名对照受试者进行了检测。皮内试验在患者中总是呈阳性,但诱发了两例假阳性反应。所有点刺试验方法均出现假阴性反应。多测试装置产生的反应介于点刺试验和皮内试验之间。