Crapo R O, Morris A H, Clayton P D, Nixon C R
Bull Eur Physiopathol Respir. 1982 May-Jun;18(3):419-25.
Total lung capacity (TLC), functional residual capacity, residual volume, and corresponding 95% confidence intervals were measured in 245 healthy nonsmoking person (122 women, 123 men) using a single-breath helium technique. Prediction equations for lung volumes were generated by multiple linear regression. The resultant equations are similar to previously published equations using multiple-breath gas equilibration techniques. Measured 95% confidence intervals can be closely approximated by using two times the standard error of the estimate for each equation, but cannot be approximated by using +/- 20% of the predicted value. Radiographic TLC was not significantly different from the helium dilution TLC.
采用单次呼吸氦气技术,对245名健康非吸烟人士(122名女性,123名男性)测量了肺总量(TLC)、功能残气量、残气量及相应的95%置信区间。通过多元线性回归生成了肺容积的预测方程。所得方程与先前发表的使用多次呼吸气体平衡技术的方程相似。每个方程的测量95%置信区间可以通过将估计标准误差乘以2来近似,但不能通过预测值的±20%来近似。X线胸片测量的肺总量与氦稀释法测量的肺总量无显著差异。