Padayachee T S, Lewis R R, Gosling R G
Br J Surg. 1982 Apr;69(4):218-22. doi: 10.1002/bjs.1800690417.
Doppler-shift ultrasound with spectral analysis permits the measurement of the relative heights of systolic peaks (the A/B ratio) in blood velocity sonograms from supra-orbital and common carotid arteries, the temporal artery occlusion test, the common carotid resistance index and transit times of flow-velocity waves in the internal carotid pathway. The results are compared with 201 carotid angiograms and expressed in terms of sensitivity (true positive) and specificity (true negative). Supra-orbital and common carotid A/B ratios, in combination with the temporal artery occlusion test, detected all grades of carotid artery disease with a sensitivity of 72 per cent and a specificity of 93 per cent. The corrected transit time gave a sensitivity of 57 per cent and a specificity of 89 per cent, whilst the Resistance Index gave a sensitivity of 60 per cent and a specificity of 80 per cent. The values of ultrasound parameters associated with severe disease, defined as reductions in lumen diameter of 75 per cent or more, of the internal carotid artery are examined. The temporal artery occlusion test gave a sensitivity of 91 per cent and a specificity of 94 per cent. These results were more accurate than those obtained for the corrected transit time (sensitivity 83 per cent, specificity 92 per cent) and for the Resistance Index (sensitivity 75 per cent and specificity 92 per cent). The results show that of the tests described the supra-orbital and common carotid artery A/B ratios, together with the temporal artery occlusion test, gave the best sensitivity and specificity for detection of both severe and minor carotid bifurcation disease.
采用频谱分析的多普勒频移超声可测量眶上动脉和颈总动脉血流速度超声图中收缩期峰值的相对高度(A/B比值)、颞动脉闭塞试验、颈总动脉阻力指数以及颈内动脉通路中血流速度波的通过时间。将结果与201例颈动脉血管造影结果进行比较,并以敏感度(真阳性)和特异度(真阴性)表示。眶上动脉和颈总动脉的A/B比值,结合颞动脉闭塞试验,对各等级颈动脉疾病的检测敏感度为72%,特异度为93%。校正通过时间的敏感度为57%,特异度为89%,而阻力指数的敏感度为60%,特异度为80%。研究了与严重疾病相关的超声参数值,严重疾病定义为颈内动脉管腔直径减少75%或更多。颞动脉闭塞试验的敏感度为91%,特异度为94%。这些结果比校正通过时间(敏感度83%,特异度92%)和阻力指数(敏感度75%,特异度92%)所获得的结果更准确。结果表明,在所描述的检测方法中,眶上动脉和颈总动脉的A/B比值,连同颞动脉闭塞试验,对检测严重和轻度颈动脉分叉疾病具有最佳的敏感度和特异度。