[汞柱式体积描记法。与标准静脉造影术相比的敏感性和特异性(作者译)]

[Mercury gauge plethysmography. Sensitivity and specificity compared with standard phlebography (author's transl)].

作者信息

Boccalon H

出版信息

J Mal Vasc. 1982;7(1):85-91.

PMID:7077178
Abstract

Mercury strain gauge plethysmography with programme and ECG synchronous venous occlusion was tested in 14 normal subjects (28 lower limbs). The results obtained in the case of recent deep venous thrombosis of the lower limbs were compared with those of phlebography ni 39 patients: 26 proximal thromboses and 15 calf thromboses. Interpretation of the results must take into account the strict conditions under which the plethysmography was carried out: position of the subject and especially of the lower limbs and the technical characteristics of the apparatus used. Specificity was 96.4% for the group of normal subjects. Sensitivity calculated for all the cases of venous thrombosis studied was 97.5% whilst it was 100% for proximal thromboses (femoral and iliac).

摘要

对14名正常受试者(28条下肢)进行了带有程序和心电图同步静脉阻塞的水银应变计体积描记法测试。将下肢近期深静脉血栓形成患者的结果与39例静脉造影患者的结果进行了比较:26例近端血栓形成和15例小腿血栓形成。结果的解释必须考虑到进行体积描记法时的严格条件:受试者尤其是下肢的位置以及所用仪器的技术特性。正常受试者组的特异性为96.4%。对所有研究的静脉血栓形成病例计算的敏感性为97.5%,而近端血栓形成(股静脉和髂静脉)的敏感性为100%。

相似文献

1
[Mercury gauge plethysmography. Sensitivity and specificity compared with standard phlebography (author's transl)].[汞柱式体积描记法。与标准静脉造影术相比的敏感性和特异性(作者译)]
J Mal Vasc. 1982;7(1):85-91.
2
[Impedance plethysmography. Comparison of sensibility and specificity in recent deep venous thromboses of the lower limbs (author's transl)].
J Mal Vasc. 1982;7(1):81-4.
3
Detection of deep vein thrombosis with an automatic electrically calibrated strain gauge plethysmograph.使用自动电校准应变计体积描记器检测深静脉血栓形成
Surgery. 1977 Aug;82(2):219-23.
4
[Thromboembolic disease in pneumology. Value of mercury-gauge plethysmography with venous occlusion].[呼吸病学中的血栓栓塞性疾病。静脉阻塞式汞柱体积描记法的价值]
Rev Mal Respir. 1985;2(3):133-8.
5
Diagnosis of deep vein thrombosis by combination of Doppler ultrasound flow examination and strain gauge plethysmography. An alternative to venography only in particular conditions despite improved accuracy of the Doppler method.通过多普勒超声血流检查和应变计体积描记法联合诊断深静脉血栓形成。尽管多普勒方法的准确性有所提高,但仅在特定情况下可替代静脉造影。
Thromb Haemost. 1982 Apr 30;47(2):141-4.
6
Computerized strain-gauge plethysmography - An alternative method for the detection of lower limb deep venous thrombosis?计算机应变计体积描记法——检测下肢深静脉血栓形成的一种替代方法?
Clin Radiol. 2000 Jan;55(1):36-9. doi: 10.1053/crad.1999.0332.
7
The clinical significance of biphasic venous emptying curves from the lower limb in venous occlusion plethysmography.
Scand J Clin Lab Invest. 1975 Oct;35(6):497-506.
8
[A mathematical analysis of strain-gauge curves in the diagnosis of deep venous thrombosis].[应变计曲线在深静脉血栓形成诊断中的数学分析]
Angiologia. 1991 May-Jun;43(3):118-21.
9
Segmental air plethysmography in the diagnosis of deep vein thrombosis.
Surg Gynecol Obstet. 1987 Dec;165(6):488-90.
10
[Present methods of diagnosis of deep vein thrombosis of the lower limbs (author's transl)].[下肢深静脉血栓形成的当前诊断方法(作者译)]
Ann Cardiol Angeiol (Paris). 1981 May;30(3):145-50.

引用本文的文献

1
Double-blind plethysmographic study of venous effects of heptaminol adenosine phosphate in patients with primary varicose veins.
Eur J Clin Pharmacol. 1989;37(1):37-40. doi: 10.1007/BF00609421.