Schaefer G J, Bonsall R W, Michael R P
Physiol Behav. 1982 Jul;29(1):163-5. doi: 10.1016/0031-9384(82)90382-1.
This paper describes a biphasic, constant-current stimulator that is appropriate for intracranial self-stimulation (ICSS) studies. The stimulator is made from components that are readily available in electronic supply stores at low cost. A printed circuit board has also been designed for the stimulator which facilitates its production. The device has proven extremely reliable in various ICSS paradigms.
本文介绍了一种适用于颅内自我刺激(ICSS)研究的双相恒流刺激器。该刺激器由电子用品商店中 readily available 且成本低廉的元件制成。还为该刺激器设计了印刷电路板,这便于其生产。在各种ICSS范式中,该设备已证明极其可靠。