The Tenckhoff catheter for peritoneal dialysis--an appraisal.

作者信息

Rubin J, Adair C M, Raju S, Bower J D

出版信息

Nephron. 1982;32(4):370-4. doi: 10.1159/000182882.

Abstract

We prospectively evaluated early (within 40 days) catheter complications in all patients receiving a dialysis catheter between 1/8/80 and 1/8/81. 50% of patients achieved a functioning catheter at the first insertion and 24% required replacement of the catheter because of poor dialysate flow. Leaking from the catheter exit site occurred in 20%, infection at the exit site in 9% and peritonitis in 19% of patients. In patients who maintain a catheter over 40 days and undergo treatment by long-term peritoneal dialysis median catheter survival was 400 days with delayed cytheter failure primarily due to failure to resolve a clinical episode of peritonitis. Although the Tenckhoff catheter is readily inserted frequent complications occur.

摘要

我们前瞻性评估了1980年8月1日至1981年8月1日期间所有接受透析导管置入的患者的早期(40天内)导管并发症。50%的患者在首次置入时导管功能良好,24%的患者因透析液流量不佳需要更换导管。20%的患者出现导管出口处渗漏,9%的患者出口处感染,19%的患者发生腹膜炎。在留置导管超过40天并接受长期腹膜透析治疗的患者中,导管中位生存期为400天,导管延迟失败主要是由于腹膜炎临床发作未能得到解决。尽管Tenckhoff导管易于置入,但仍会频繁出现并发症。