Abstract

Twenty-four comatose patients were studied by 16-hour compressed spectral array (CSA), made from four-channel portable EEG recordings. Causes of coma included head injury (15), anoxia (6), and brainstem strokes (3). CSA was classified on the basis of frequency and alternating or nonalternating patterns. Alternating CSA was significantly associated with survival (p less than 0.005) in the head-injured and anoxic group combined, and in the head-injured subgroup (p less than 0.013). The prognostic value of CSA equaled the Glasgow Coma Scale or neurologic examination and occasionally added prognostic information.

摘要

对24名昏迷患者进行了研究,通过四通道便携式脑电图记录制作16小时压缩谱阵图(CSA)。昏迷原因包括头部受伤(15例)、缺氧(6例)和脑干中风(3例)。CSA根据频率以及交替或非交替模式进行分类。在合并的头部受伤和缺氧组以及头部受伤亚组中,交替CSA与存活显著相关(p<0.005)(p<0.013)。CSA的预后价值等同于格拉斯哥昏迷量表或神经学检查,偶尔还能提供额外的预后信息。