A simple assay method for platelet factor 4 is described. When factor Xa was added to a system containing antithrombin III in excess and heparin in low concentration, the amount of factor Xa immediately inactivated was found to be a function of the concentration of heparin. When an antiheparin such as platelet factor 4 was added, an increase of the residual activity of factor Xa was observed. The magnitude of this increase was shown to be correlated to the amount of heparin inactivation in the system. Platelet factor 4 could be assayed when the concentrations of antithrombin III, heparin, and factor Xa were maintained at a constant level and in excess. As an indicator of the reaction, factor Xa was measured with the chromogenic substrate benzoyl-Ile-Gou-Gly-Arg-p-nitroanilide (S-2222).

摘要

本文描述了一种检测血小板第4因子的简单方法。当将凝血因子Xa加入到含有过量抗凝血酶III和低浓度肝素的体系中时,发现立即被灭活的凝血因子Xa的量是肝素浓度的函数。当加入抗肝素物质如血小板第4因子时,可观察到凝血因子Xa的残余活性增加。这种增加的幅度与体系中肝素的失活量相关。当抗凝血酶III、肝素和凝血因子Xa的浓度保持恒定且过量时,可检测血小板第4因子。作为反应的指标,使用发色底物苯甲酰-Ile-Glu-Gly-Arg-对硝基苯胺(S-2222)来检测凝血因子Xa。