The polarographic measurement of halothane.

作者信息

Albery W J, Hahn C E, Brooks W N

出版信息

Br J Anaesth. 1981 May;53(5):447-54. doi: 10.1093/bja/53.5.447.

Abstract

The polarographic reduction of halothane on silver cathodes was studied. Silver catalyses the reduction of halothane: two electrons are exchanged in the reduction process. Experiments using a rotating disc electrode showed a linear relationship between observed current and halothane concentration. A Silastic membrane-covered polarographic electrode was constructed using a silver cathode which gave a good linear response to changes in halothane concentration over the range 0.5% v/v halothane in nitrogen. Oxygen interferes with the measurement of halothane, but can be removed from a gas sample before analysis.

摘要

研究了氟烷在银阴极上的极谱还原。银催化氟烷的还原:在还原过程中有两个电子交换。使用旋转圆盘电极的实验表明,观察到的电流与氟烷浓度之间呈线性关系。使用银阴极构建了一个覆盖硅橡胶膜的极谱电极,该电极在氮气中0.5% v/v氟烷范围内对氟烷浓度变化给出良好的线性响应。氧气会干扰氟烷的测量,但可在分析前从气体样品中除去。