Abstract

The specificity of 7 different binding proteins (4 antibodies and 3 transins) was investigated in human urine. Pregnant and nonpregnant urine samples were extracted and chromatographed, and values were compared before and after chromatography. Without chromatography, all methods grossly overestimated the amount of cortisol present. Four methods gave higher values than the other 3 even after chromatography, possibly due to cross-reactivity with 20-dihydrocortisone which coelutes in part with cortisol. Interference also occurred in both the less polar and the more polar regions of the chromatograms with all assay systems. Values for a series of 20 urines were closely similar for the RTAs but widely divergent for the RIAs. Close correlations were found for all of the RTAs with each other and with the RIAs if simple methylene chloride extraction was used. A high degree of correlation was also found between extracted and unextracted urine values in the 4 systems studied. Cortisol values by RTA (dog transcortin) after chromatography on Sephadex LH-20 gave mean values of 20.5 +/- 9.7 microgram/day in men, 14.0 +/- 5.7 micrograms/day in cycling women, and 38.0 +/- 24.5 micrograms/day in women in late pregnancy (n = 6 in each group). It is concluded that there is no simple practical method currently available for true cortisol in urine, but that the measurement of adrenal corticoids in urine can afford an accurate reflection of adrenocortical function provided there is no gross metabolic abnormality present and that the normal range is carefully established for each particular method used.

摘要

在人尿液中研究了7种不同结合蛋白(4种抗体和3种转运蛋白)的特异性。提取并对妊娠和非妊娠尿液样本进行色谱分析,比较色谱分析前后的值。在未进行色谱分析时,所有方法都严重高估了尿液中皮质醇的含量。即使在色谱分析后,仍有4种方法的值高于其他3种方法,这可能是由于与部分与皮质醇共洗脱的20 - 二氢皮质醇发生交叉反应。在所有检测系统的色谱图中,极性较小和极性较大的区域均出现干扰。一系列20份尿液样本的放射免疫分析法(RIA)值差异很大,但放射受体分析法(RTA)值非常相似。如果使用简单的二氯甲烷萃取法,所有RTA之间以及RTA与RIA之间都发现了密切的相关性。在所研究的4种系统中,提取和未提取尿液的值之间也发现了高度相关性。在Sephadex LH - 20上进行色谱分析后,用RTA(狗皮质激素转运蛋白)测得的男性皮质醇值平均为20.5±9.7微克/天,处于月经周期的女性为14.0±5.7微克/天,妊娠晚期女性为38.0±24.5微克/天(每组n = 6)。结论是,目前尚无简单实用的方法来测定尿液中的真正皮质醇,但只要不存在严重的代谢异常且为所使用的每种特定方法仔细确定正常范围,尿液中肾上腺皮质激素的测量就能准确反映肾上腺皮质功能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验