Yasuda J, Ueno G, Kuratsuka K, Homma R, Hara S, Kazama M, Ito H
Dev Biol Stand. 1980;48:143-52.
The following amendments have been introduced to the Minimum Requirements for Human Serum Albumin (HSA) and Plasma Protein Fraction (PPF): 1) The upper limit of sodium content was fixed at 3.7 mg/ml; 2) test for chloride content was introduced; 3) sodium and chloride contents were required to be stated on the label; 4) use of zone electrophoresis was introduced in addition to the free-boundary electrophoresis; and 5) albumin content in HSA was lowered from 97% to 96%. Moreover, current problems in quality control which may require further amendments were discussed, namely: 1) limulus amoebocyte lysate test to replace or supplement the pyrogen test in rabbits; 2) attempt of quantitative expression of visual turbidity; 3) establishment of reference A and B blood group substances; 4) gel permeation analysis and scanning at 370-800 nm; and 5) test for prekallikrein activator (PKA).
已对人血清白蛋白(HSA)和血浆蛋白组分(PPF)的最低要求做出以下修订:1)钠含量上限固定为3.7毫克/毫升;2)引入了氯化物含量检测;3)要求在标签上标明钠和氯化物含量;4)除自由界面电泳外,引入了区带电泳;5)HSA中的白蛋白含量从97%降至96%。此外,还讨论了可能需要进一步修订的当前质量控制问题,即:1)用鲎试剂检测替代或补充家兔热原检测;2)尝试对视觉浊度进行定量表达;3)建立A和B血型参考物质;4)凝胶渗透分析及在370 - 800纳米处扫描;5)前激肽释放酶激活剂(PKA)检测。