Suppr超能文献

脉冲超声对哺乳动物脑电图无影响。

Lack of effect of pulsed ultrasound on the mammalian EEG.

作者信息

Amin A, Foster K R, Ternes J, Takashima S

出版信息

Aviat Space Environ Med. 1981 Oct;52(10):604-7.

PMID:7295247
Abstract

Anesthetized rhesus monkeys and rabbits were exposed to pulsed ultrasound, from a 1.8 cm diameter transducer placed against the head. Each ultrasonic exposure lasted 4 min; it consisted of a series of 1-2 mu sec pulses, with a frequency spectrum broadly centered about the transducer resonant frequency of 1.5 MHz, repeated at a rate of 950 Hz. The time averaged ultrasonics power was 12.6 mW, with an estimated peak power of ca. 15 watts. No changes were observed in the EEG or its power spectrum during or immediately after the exposure. This contrasts to a previous report of significant changes in the EEG of squirrel monkeys during comparable exposures to pulsed ultrasound. Analysis of the earlier reported results suggests that some of the "effects" were due to aliasing artifacts.

摘要

将麻醉后的恒河猴和兔子头部放置一个直径为1.8厘米的换能器,使其暴露于脉冲超声下。每次超声暴露持续4分钟;由一系列1 - 2微秒的脉冲组成,频谱大致以1.5兆赫兹的换能器共振频率为中心,以950赫兹的速率重复。时间平均超声功率为12.6毫瓦,估计峰值功率约为15瓦。在暴露期间或暴露后立即观察到脑电图(EEG)或其功率谱没有变化。这与之前一份关于松鼠猴在类似脉冲超声暴露期间脑电图有显著变化的报告形成对比。对早期报告结果的分析表明,一些“效应”是由于混叠伪像造成的。