Abstract

The 4-year experience with flexible fibre-optic bronchoscopy at Groote Schuur Hospital is presented. A total of 809 patients were bronchoscoped, follow-up data on 705 being available. The procedure was performed for a wide variety of indications, suspected malignant disease and tuberculosis being the two most common. The diagnostic rate in these conditions was 74% and 71% respectively. Other indications included the evaluation of diffuse pulmonary lesions, shadows on the chest radiographs in immunocompromised patients, use in the intensive care unit, investigation of haemoptysis with a normal chest radiograph, inspection of the airway, bronchography and clearance of secretions.

摘要

本文介绍了格罗特·舒尔医院4年的可弯曲纤维支气管镜检查经验。共有809例患者接受了支气管镜检查,其中705例有随访数据。该检查用于多种适应证,最常见的两种是疑似恶性疾病和肺结核。在这些情况下的诊断率分别为74%和71%。其他适应证包括评估弥漫性肺部病变、免疫功能低下患者胸部X光片上的阴影、在重症监护病房的应用、胸部X光片正常的咯血检查、气道检查、支气管造影和分泌物清除。