[Central venous catheterization using ECG monitoring and its obstetrical application (author's transl)].

作者信息

Ohta C, Ohkusa T, Tamada T

出版信息

Acta Obstet Gynaecol Jpn. 1981 Jul;33(7):1025-34.

PMID:7304128
Abstract

We tried the central venous catheterization using the ECG monitoring lead by the catheter tip without the X-ray examination. The catheter consists of 5F sized, 70 cm, thin-walled polyethylene tube. The apex of the catheter is 60 degrees curved with heating and the exchangeable metal adaptor is attached in the proximal end. The catheter was introduced percutaneously into the cubital vein and filled with saline. The ECG lead from the catheter tip was recorded through the metal adaptor by the battery electrocardiograph. The introduction into the right atrium of the catheter was easily judged in almost all cases by the intraatrial ECG, namely, deep negative or biphasic P wave. We have tried this method in 72 cases and the success rate of insertion into the right atrium was as high as 87.5%. The right atrial pressure of the obstetrical group (19 term pregnant women) was significantly lower than that of the gynecological group (22 preoperative patients) (P less than 0.01). The pH of the right atrial blood in the obstetrical group was significantly higher than that in the gynecological group (P less than 0.01). PCO2, PO2, HCO3-, and the oxygen saturation of the obstetrical group were significantly lower than those of the gynecological group (P less than 0.01).

摘要

相似文献

1
[Central venous catheterization using ECG monitoring and its obstetrical application (author's transl)].
Acta Obstet Gynaecol Jpn. 1981 Jul;33(7):1025-34.
2
The intracavitary electrocardiogram: a routine bedside procedure elucidating obscure arrhythmias. A study in 60 patients.
Isr J Med Sci. 1975 May;11(5):409-19.
3
[Positioning of central venous catheters using ECG].[使用心电图定位中心静脉导管]
Tidsskr Nor Laegeforen. 1991 Feb 20;111(5):599-601.
4
Application of intravenous electrocardiography for insertion of central veins dialysis catheters.静脉心电图在中心静脉透析导管置入中的应用。
Saudi J Kidney Dis Transpl. 2009 Sep;20(5):794-7.
5
Comparison of P waves recorded on the standard electrocardiogram, the "Lewis lead," and "saline-filled central venous catheter"-based intracardiac electrocardiogram.标准心电图、“Lewis导联”及基于“盐水填充中心静脉导管”的心内心电图所记录的P波比较。
Am J Cardiol. 2004 Aug 15;94(4):474-8. doi: 10.1016/j.amjcard.2004.05.006.
6
[Accurate placement of central venous catheter--ECG-guided method vs patient height method].[中心静脉导管的精准放置——心电图引导法与患者身高法]
Masui. 2002 Jan;51(1):34-8.
7
Central venous catheters--the inability of 'intra-atrial ECG' to prove adequate positioning.中心静脉导管——“心房内心电图”无法证实其位置合适
Br J Anaesth. 2004 Aug;93(2):193-8. doi: 10.1093/bja/aeh191. Epub 2004 Jun 25.
8
[Extravasal position of central venous catheters despite unsuspicious ECG-guidance].[尽管心电图引导无异常,但中心静脉导管出现血管外位置]
Anasthesiol Intensivmed Notfallmed Schmerzther. 2005 Feb;40(2):91-6. doi: 10.1055/s-2004-826142.
9
[Accurate placement of central venous catheters using right atrial electrocardiography].[使用右心房心电图进行中心静脉导管的精准放置]
Masui. 1996 Mar;45(3):326-30.
10
[Clinical use of a new cava catheter with an ECG lead over a steel mandrin].[一种带有置于钢丝芯上的心电图导联的新型腔静脉导管的临床应用]
Anaesthesist. 1990 Apr;39(4):240-2.