A new method based on computer-assisted semi-automatic equipment for stereological analysis has been developed to measure ulcer size endoscopically. The main component is a graphic measuring table connected with a computer which is itself linked to a television monitor. The endoscopic picture is transmitted to the television monitor and the ulcer area is measured directly on the monitor using electronic overlay markers. The trace of the measuring markers remains visible on the monitor so that every lesion demonstrated is accurately outlined. The computer calculates the ulcer area by relating it to a known endoscopically inserted reference area. Numerous measurements from various distances, various angles of view and with variable reference area sizes showed the error to be 4.2 +/- 0.5%. Measurements by six different investigators showed variations of 2.9 +/- 1.2%. These results document the reliability of endoscopic planimetrics of gastrointestinal ulcers.

摘要

已开发出一种基于计算机辅助半自动设备的新方法用于体视学分析,以在内镜下测量溃疡大小。主要部件是一个与计算机相连的图形测量台,计算机又与电视监视器相连。内镜图像传输到电视监视器上,使用电子叠加标记在监视器上直接测量溃疡面积。测量标记的轨迹在监视器上保持可见,以便准确勾勒出每个显示的病变。计算机通过将溃疡面积与已知的内镜插入参考面积相关联来计算溃疡面积。从不同距离、不同视角以及不同参考面积大小进行的大量测量显示误差为4.2±0.5%。六位不同研究者的测量显示变异为2.9±1.2%。这些结果证明了胃肠道溃疡内镜平面测量法的可靠性。