Bacteria of the type E. coli K12 have been treated in experiments using high-voltage pulses of short time (microseconds) as a killing agent. The role of different experimental parameters has been studied: kind of electrolyte, concentration, length of pulses, field strength, pH and temperature. Electrolytes with bivalent cations were found to reduce the lethal action. the relative rate of killed bacteria was shown to be mainly governed by the field strength and the treatment time, which is defined by the product of pulse number and decay time constant. From the obtained results a function has been developed which enables the precalculation of the killing rate for E. coli, provided that certain limits of experimental conditions are considered. No correlation between the applied electric energy and the lethal effect could be found.

摘要

在实验中,已使用短时间(微秒级)的高压脉冲作为杀菌剂来处理大肠杆菌K12型细菌。研究了不同实验参数的作用:电解质种类、浓度、脉冲长度、场强、pH值和温度。发现含有二价阳离子的电解质会降低致死作用。结果表明,被杀死细菌的相对速率主要由场强和处理时间决定,处理时间由脉冲数与衰减时间常数的乘积定义。根据所得结果,已开发出一种函数,只要考虑实验条件的某些限制,就能预先计算大肠杆菌的杀灭率。未发现施加的电能与致死效应之间存在相关性。