Suppr超能文献

近视散光作为人工晶状体眼调节替代方式

Myopic astigmatism as a substitute for accommodation in pseudophakia.

作者信息

Huber C

出版信息

Dev Ophthalmol. 1981;5:17-26. doi: 10.1159/000400931.

Abstract

Pseudophacic eyes can be made nearly spectacle-independent by increasing the depth of focus of the uncorrected implanted eye. When the postoperative ametropia is a simple myopic astigmatism the uncorrected visual acuity can be above 0.4 from far to near. The quasi-constant visual acuity in different distances is due to the slow change in the dimension of the blurred retinal image when a point source comes nearer to a myopic astigmatic eye. The intersection of Sturm's conoid and the retina (i.e. the blur spot) changes mainly in form but its size changes much less than in a sperical ametropia. To obtain such a refraction the dioptric change in corneal power induced by surgery must be included in the calculation of the intraocular lens. The induced corneal ametropia is a mixed astigmatism with no equivalent power. The optical principles and the clinical results obtained with iridocapsular Binkhorst lenses are discussed.

摘要

通过增加未矫正的植入眼的焦深,可使假晶状体眼几乎不依赖眼镜。当术后屈光不正为单纯近视散光时,未矫正视力在远近距离均可高于0.4。不同距离下近乎恒定的视力是由于当点光源靠近近视散光眼时,视网膜模糊像尺寸的缓慢变化所致。斯图姆圆锥与视网膜的交点(即模糊斑)主要在形状上发生变化,但其大小变化远小于球面屈光不正。为获得这种屈光状态,手术引起的角膜屈光力变化必须包含在人工晶状体的计算中。诱导性角膜屈光不正是一种无等效屈光力的混合散光。本文讨论了虹膜囊袋式宾克霍斯特人工晶状体的光学原理及临床结果。