Intravenous home blood glucose monitoring.

作者信息

Schade D S, Eaton R P, Mitchell W J, Friedman N M

出版信息

Diabetes Care. 1981 May-Jun;4(3):420-3. doi: 10.2337/diacare.4.3.420.

DOI:10.2337/diacare.4.3.420
PMID:7344892
Abstract

This study examines the correlation between the blood glucose concentration estimated by diabetic subjects at home using a Chemstrip bG reagent strip, and the blood glucose concentration subsequently measured in a Beckman glucose analyzer. Blood samples were obtained by eight diabetic patients throughout a period of 30 days in the home environment. Using the technique of i.v. blood withdrawal, a 250-microliters portion of each blood sample was stored for later physician verification of the blood glucose concentration. The preservative in these stored sampled inhibited the utilization of glucose in the blood samples for at least 30 days. Our results demonstrate that in the home setting, a highly significant correlation (R = 0.85, P less than 0.001) can be obtained between the plasma glucose concentration as estimated by Chemstrip bGs and the blood glucose concentration as estimated by Beckman automated glucose analysis. However, within the diabetic group, marked variation existed in correlation coefficients such that the highest correlation coefficient was 0.94, and the lowest was 0.72. Furthermore, the use of Chemstrip bGs tends to influence a patient's reading toward the preselected color chart of glucose concentration on the Chemstrip bG label. We conclude that i.v. home blood glucose monitoring provides a method whereby the physician can assess the accuracy with which his patients can monitor their blood glucose concentrations in a home environment.

摘要

相似文献

1
Intravenous home blood glucose monitoring.
Diabetes Care. 1981 May-Jun;4(3):420-3. doi: 10.2337/diacare.4.3.420.
2
A comparison of accuracy and estimated cost of methods for home blood glucose monitoring.家用血糖监测方法的准确性与估计成本比较。
Diabetes Care. 1981 May-Jun;4(3):396-403. doi: 10.2337/diacare.4.3.396.
3
Self-monitoring of blood glucose without a meter.
Diabetes Care. 1981 May-Jun;4(3):414-6. doi: 10.2337/diacare.4.3.414.
4
Assessment of a new blood glucose strip: comparison of Visidex, Visidex II, and Chemstrip bG with Glucose Analyzer determination of blood glucose.
Diabetes Care. 1985 Jan-Feb;8(1):77-82. doi: 10.2337/diacare.8.1.77.
5
Comparative study of home blood glucose monitoring devices: Visidex, Chemstrip bG, Glucometer, and Accu-Chek bG.
Diabetes Care. 1983 Nov-Dec;6(6):529-32. doi: 10.2337/diacare.6.6.529.
6
Evaluation of two methods of self blood glucose monitoring by trained insulin-dependent diabetic adolescents outside the hospital.由经过培训的胰岛素依赖型糖尿病青少年在院外对两种自我血糖监测方法进行评估。
Diabetes Care. 1983 Mar-Apr;6(2):166-9. doi: 10.2337/diacare.6.2.166.
7
Bedside blood glucose determinations in critical care medicine: a comparative analysis of two techniques.
Crit Care Med. 1982 Jul;10(7):463-5. doi: 10.1097/00003246-198207000-00012.
8
Stability of reacted Chemstrip bG.
Diabetes Care. 1988 Mar;11(3):288-91. doi: 10.2337/diacare.11.3.288.
9
A comparison study of blood glucose test strips.血糖测试条的比较研究。
Diabetes Care. 1981 May-Jun;4(3):407-11. doi: 10.2337/diacare.4.3.407.
10
Comparison of Visidex and Chemstrip bG with Beckman Glucose Analyzer determination of blood glucose.
Diabetes Care. 1983 Nov-Dec;6(6):536-9. doi: 10.2337/diacare.6.6.536.