Coronary and systemic circulations, and contractility and oxygen consumption of the left ventricular myocardium were depressed as arterial enflurane concentration increased in acute experiments with 22 adult mongrel dogs. Uneven transmural blood flow in the left ventricular free wall did not appear and the inner/outer ratio remained near 1.0 until a very deep stage of the anesthesia was attained and as far as diastolic aortic pressure was maintained above 40 mmHg, according to the microsphere injection study. Once diastolic pressure fell below 35--40 mmHg, the ratios started to be reduced significantly. When arterial enflurane content reached 53.0 +/- 2.1 mg/100 ml (mean +/- s.e.), the ratio became 0.84 +/- 0.08 (p less than 0.001), and simultaneously calculated DPTI/TTI ratio also showed a significant redution from the control (0.79 +/- 0.03, p less than 0.001). The I/O and DPTI/TTI ratios, however, did not correlate significantly with each other until very deep enflurane anesthesia was attained. The lower limit of autoregulation of coronary vascular bed was suggested to be near 35--40 mmHg of diastolic aortic pressure during deep enflurane anesthesia in the dog. Among systolic time intervals measured directly during the study, PEP and ICT showed significant negative correlations with Vmax and LV dp/dt max, while LVET neither changed nor correlated significantly with stroke volume or other parameters representing myocardial contractility during the course of enflurane anesthesia.

摘要

在对22只成年杂种犬进行的急性实验中,随着动脉恩氟烷浓度的增加,冠状动脉和体循环以及左心室心肌的收缩性和氧耗量均降低。根据微球注射研究,在达到非常深的麻醉阶段之前,左心室游离壁跨壁血流不均一的情况未出现,内膜/外膜比值保持在1.0左右,并且只要舒张压维持在40 mmHg以上。一旦舒张压降至35 - 40 mmHg以下,该比值开始显著降低。当动脉恩氟烷含量达到53.0±2.1 mg/100 ml(均值±标准误)时,该比值变为0.84±0.08(p<0.001),同时计算得出的DPTI/TTI比值也较对照组显著降低(0.79±0.03,p<0.001)。然而,直到达到非常深的恩氟烷麻醉状态,内膜/外膜比值与DPTI/TTI比值之间才具有显著相关性。在犬深度恩氟烷麻醉期间,冠状动脉床自动调节的下限被认为接近舒张期主动脉压35 - 40 mmHg。在研究期间直接测量的收缩期时间间隔中,PEP和ICT与Vmax和LV dp/dt max呈显著负相关,而在恩氟烷麻醉过程中,LVET既无变化,也与每搏量或其他代表心肌收缩性的参数无显著相关性。

相似文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验