Prior R B, Spagna V A
J Clin Microbiol. 1980 Apr;11(4):340-2. doi: 10.1128/jcm.11.4.340-342.1980.
Eighty-one men with exudative urethritis were evaluated on initial visit for gonococcal urethritis by using the standard tube and newly developed microdilution Limulus amoebocyte lysate techniques. Serial dilutions of clinical specimens ranging from 1:100 to 1:102,400 were each tested, and results correlated with Gram stain and culture. Overall accuracy for predicting culture results was 98% for a dilution of 1:200 and 99% for a dilution of 1:400 for the tube and microdilution techniques, respectively. The microdilution technique predicted culture results in 98% of cases for dilutions ranging from 1:400 to 1:1,600, whereas the tube technique was as accurate for dilutions of only 1:100 and 1:200. The microdilution Limulus amoebocyte lysate technique was a rapid, reliable, sensitive, and economical diagnostic aid in the initial evaluation of exudative urethritis in men.
81名患有渗出性尿道炎的男性在初诊时通过使用标准试管法和新开发的微量稀释鲎试剂法来评估淋菌性尿道炎。对临床标本从1:100到1:102,400进行系列稀释并分别进行检测,结果与革兰氏染色和培养结果相关。对于试管法和微量稀释法,预测培养结果的总体准确率在稀释度为1:200时分别为98%,在稀释度为1:400时分别为99%。微量稀释法在稀释度为1:400至1:1,600时对98%的病例预测了培养结果,而试管法仅在稀释度为1:100和1:200时具有同样的准确性。微量稀释鲎试剂法在男性渗出性尿道炎的初步评估中是一种快速、可靠、灵敏且经济的诊断辅助方法。