Comparison of personal pollution monitoring techniques for use in the operating room.

作者信息

Campbell D, Davis P D, Halliday M M, MacDonald I

出版信息

Br J Anaesth. 1980 Sep;52(9):885-92. doi: 10.1093/bja/52.9.885.

Abstract

Three personal pollution monitors (adsorption tubes, diffusion dosimeters and evacuated bottles) have been tested, in routinely used operating rooms and under controlled laboratory conditions, for their accuracy and reproducibility relative to one another and to measurements by infra-red spectroscopy. All the techniques provide time-weighted average measurements of pollutant concentrations. Tubes and dosimeters measure halothane with greater accuracy than that required by N.I.O.S.H. regulations, but neither technique can measure inorganic pollutants such as nitrous oxide. The prototype evacuated bottles tested are unsatisfactory at their present stage of development for the measurement of both halothane and nitrous oxide concentrations. We believe that, at the present time, surveys of operating room pollution can best be carried out using adsorption tubes of diffusion dosimeters for personal halothane concentrations and a portable infra-red spectrometer for measurement of background nitrous oxide concentrations.

摘要