Frequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.

作者信息

Stein P D, Sabbah H N, Lakier J B, Magilligan D J, Goldstein D

出版信息

Circulation. 1981 Jan;63(1):200-3. doi: 10.1161/01.cir.63.1.200.

DOI:10.1161/01.cir.63.1.200
PMID:7438394
Abstract

The frequency spectrum of the first heart sound (S1) was measured noninvasively in 54 patients with porcine bioprosthetic valves inserted in the mitral position. Phonocardiograms were recorded on magnetic tape on line with a signal processor with which the frequency spectrum and peak frequency of S1 were determined. In 19 patients with normal natural mitral valves, the apparent peak frequency within the range of measured frequencies of S1 was 46 +/- 2 Hz (mean +/- SEM). In 11 patients with porcine bioprosthetic valves implanted in the mitral position for less than or equal to 11/2 years, the apparent peak frequency of S1 was 43 +/- 3 Hz, which was not significantly different from S1 in patients with normal mitral valves. However, in 33 patients with porcine bioprosthetic valves in place 5-7 years, the apparent peak frequency of S1 was higher, 67 +/- 2 Hz (p < 0.001). In patients in whom the porcine bioprosthetic valve was implanted 5 years or longer, the frequency spectrum of S1 showed a greater proportion of sound energy at frequencies between 50-200 Hz compared with patients in whom the prosthetic valve was implanted 11/2 years or less. changes of the frequency of S1 in these patients may be a manifestation of stiffening of the valve as a result of early degenerative changes.

摘要

相似文献

1
Frequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.
Circulation. 1981 Jan;63(1):200-3. doi: 10.1161/01.cir.63.1.200.
2
Frequency spectra of the first heart sound and of the aortic component of the second heart sound in patients with degenerated porcine bioprosthetic valves.
Am J Cardiol. 1984 Feb 1;53(4):557-61. doi: 10.1016/0002-9149(84)90030-4.
3
[Phonoechocardiographic study on the genesis of the initial low-frequency component of the first heart sound].[第一心音起始低频成分发生机制的心音图研究]
J Cardiogr. 1982 Sep;12(3):655-65.
4
Long-term failure rate and morphologic correlations in porcine bioprosthetic heart valves.猪生物心脏瓣膜的长期故障率及形态学相关性
Am J Cardiol. 1983 Mar 15;51(6):957-64. doi: 10.1016/s0002-9149(83)80173-8.
5
Time-frequency analysis of the first heart sound: Part 3: Application to dogs with varying cardiac contractility and to patients with mitral mechanical prosthetic heart valves.
Med Biol Eng Comput. 1997 Sep;35(5):455-61. doi: 10.1007/BF02525523.
6
[Sound spectrographic investigations of heart sounds and murmurs and of the sounds produced by artificial valves (author's transl)].[心音、杂音及人工瓣膜产生的声音的声谱研究(作者译)]
Wien Klin Wochenschr Suppl. 1976;51:1-19.
7
Frequency content of heart sounds and systolic murmurs in patients with porcine bioprosthetic valves: diagnostic value for the early detection of valvular degeneration.猪生物瓣膜置换患者心音和收缩期杂音的频率成分:对瓣膜退变早期检测的诊断价值
Henry Ford Hosp Med J. 1982;30(3):119-23.
8
Diastolic rumbles in normally functioning porcine mitral valves.正常功能的猪二尖瓣舒张期隆隆声。
Chest. 1978 Feb;73(2):189-92. doi: 10.1378/chest.73.2.189.
9
Bias and variability of diagnostic spectral parameters extracted from closing sounds produced by bioprosthetic valves implanted in the mitral position.
IEEE Trans Biomed Eng. 1989 Aug;36(8):815-26. doi: 10.1109/10.30807.
10
Calcification of aortic versus mitral porcine bioprosthetic heart valves: a radiographic study comparing amounts of calcific deposits in valves explanted from the same patient.猪主动脉与二尖瓣生物人工心脏瓣膜的钙化:一项影像学研究,比较同一患者体内取出的瓣膜中钙化沉积物的数量。
Am J Cardiol. 1984 Nov 1;54(8):1030-2. doi: 10.1016/s0002-9149(84)80139-3.

引用本文的文献

1
Listening to heart sounds through the pressure waveform.通过压力波形听心音。
Sci Rep. 2024 Nov 5;14(1):26824. doi: 10.1038/s41598-024-78554-5.
2
Preoperative Significance of Ipsilateral Manual Neck Compression in Patients With Pulsatile Tinnitus Secondary to Sigmoid Sinus Dehiscences and Diverticula.乙状窦憩室和乙状窦骨壁缺损继发搏动性耳鸣患者同侧手法按压颈部的术前意义
Front Neurol. 2022 Mar 17;13:869244. doi: 10.3389/fneur.2022.869244. eCollection 2022.
3
Development of a Finger-Ring-Shaped Hybrid Smart Stethoscope for Automatic S1 and S2 Heart Sound Identification.
研发指环式混合智能听诊器以实现自动 S1 和 S2 心音识别。
Sensors (Basel). 2021 Sep 20;21(18):6294. doi: 10.3390/s21186294.
4
Stethoscope with digital frequency translation for improved audibility.具有数字频率转换功能以提高可听度的听诊器。
Healthc Technol Lett. 2019 Jul 31;6(5):143-146. doi: 10.1049/htl.2019.0011. eCollection 2019 Oct.
5
Digital stethoscope: technology update.数字听诊器:技术更新
Med Devices (Auckl). 2018 Jan 4;11:29-36. doi: 10.2147/MDER.S135882. eCollection 2018.
6
Evaluation of Karhunen-Loève expansion for feature selection in computer-assisted classification of bioprosthetic heart-valve status.
Med Biol Eng Comput. 1999 Jul;37(4):504-10. doi: 10.1007/BF02513337.
7
Comparison of spectral techniques for computer-assisted classification of spectra of heart sounds in patients with porcine bioprosthetic valves.猪生物瓣膜置换患者心音光谱计算机辅助分类的光谱技术比较
Med Biol Eng Comput. 1993 May;31(3):229-36. doi: 10.1007/BF02458041.
8
Quantification of first heart sound frequency dynamics across the human chest wall.
Med Biol Eng Comput. 1994 Jul;32(4 Suppl):S71-8. doi: 10.1007/BF02523331.
9
Artificial neural networks in computer-assisted classification of heart sounds in patients with porcine bioprosthetic valves.
Med Biol Eng Comput. 1994 May;32(3):311-6. doi: 10.1007/BF02512528.
10
Bioengineering aspects of heart valve replacement.心脏瓣膜置换的生物工程学方面