Suppr超能文献

前肢保护毛传入单位对整个感受野喷气刺激的反应。

Response of forelimb guard hair afferent units to air-jet stimulation of entire receptive field.

作者信息

Goldfinger M D, Amassian V E

出版信息

J Neurophysiol. 1980 Nov;44(5):961-78. doi: 10.1152/jn.1980.44.5.961.

Abstract
  1. In anesthetized, immobilized cats, individual axonal responses to movement of forelimb G hairs were recorded in the ipsilateral cuneate fasciculus at C1-C2 with a glass-insulated tungsten microelectrode. Several test criteria were used to identify primary afferent axons among the recorded neurons. 2. The output discharge in the parent sensory axon during continuous air-jet stimulation of the entire receptive field was irregular and was usually maintained. Criteria for statistical stability were introduced, permitting an analysis of the response as a stable point process. 3. The main interspike interval during the response to maximal air-jet stimulation ranged in different units from 4 to 100 ms, with a transition zone near 20 ms (50/s) between short and long mean interval units. Long and short mean interval units tended to be related to G2- and G1-type hair receptors, respectively. 4. In both short and long mean interval units, the interspike-interval distribution (IID) had a dead time (usually 2-4 ms), a sigmoidal rising limb, a single mode, and a monotonic falling limb, a single mode, and a monotonic falling limb. In short mean interval units, the decrement of the falling limb was described by a single exponential. 5. The value of the standard deviation of the IID was a little less than that of the mean interval minus dead time, the inequality probably resulting from the finite duration of the rising limb and, in long mean interval units, the nonexponential falling limb. 6. Joint interval analysis revealed that successive intervals were independent except in short mean interval units, where the shortest intervals tended to be followed by intervals shorter than the mean. 7. The expectation density function did not reveal any periods in the output discharge. In short mean interval units, a constant mean (planteau) level was attained after a finite rise time and usually one or more overshooting-undershooting sequences. In long mean interval units, the expectation density function monotonically rose to the plateau level. 8. Reducing the air-jet intensity caused an increase in mean interval of discharge and in standard deviation of the IID and slowed the rise time of the expectation density function to the plateau level. 9. Similarities and differences between the whole-field response to air-jet stimulation and the Poisson process are discussed.
摘要
  1. 在麻醉、固定的猫身上,用玻璃绝缘钨微电极在C1 - C2水平的同侧楔束中记录单个轴突对前肢G毛运动的反应。使用了几个测试标准来在记录的神经元中识别初级传入轴突。2. 在对整个感受野进行连续喷气刺激期间,母感觉轴突的输出放电不规则且通常持续存在。引入了统计稳定性标准,从而能够将反应作为稳定点过程进行分析。3. 在对最大喷气刺激的反应期间,不同单位的主要峰间间隔在4到100毫秒之间,在短平均间隔单位和长平均间隔单位之间,在20毫秒(50/秒)附近有一个过渡区。长平均间隔单位和短平均间隔单位往往分别与G2型和G1型毛感受器相关。4. 在短平均间隔单位和长平均间隔单位中,峰间间隔分布(IID)都有一个死区时间(通常为2 - 4毫秒)、一个S形上升支、一个单峰以及一个单调下降支。在短平均间隔单位中,下降支的衰减由单个指数描述。5. IID的标准差的值略小于平均间隔减去死区时间的值,这种不等式可能是由于上升支的有限持续时间以及在长平均间隔单位中下降支的非指数性质导致的。6. 联合间隔分析表明,连续间隔是独立的,除了在短平均间隔单位中,最短间隔之后往往跟着比平均间隔短的间隔。7. 期望密度函数未揭示输出放电中的任何周期性。在短平均间隔单位中,在有限的上升时间后达到一个恒定的平均(平稳)水平,并且通常有一个或多个过冲 - 下冲序列。在长平均间隔单位中,期望密度函数单调上升至平稳水平。8. 降低喷气强度会导致放电平均间隔和IID标准差增加,并减缓期望密度函数上升至平稳水平的时间。9. 讨论了对喷气刺激的全场反应与泊松过程之间的异同。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验